fbpx

Jeśli chcesz się z nami skontaktować w okresie od 12/20/2024 do 01/06/2025, pamiętaj, że ze względu na święta możesz spodziewać się wydłużonego czasu odpowiedzi. Dziękujemy za zrozumienie!

Reinforced concrete columns - applying the Automatic Nominal Curvature Method for design

Introduction

Reinforced concrete columns are essential structural elements in the construction industry. They are used, for example, in frame buildings, halls, family houses and bridges. They are used in both monolithic and prefabricated versions.

The designer aims to design safe and economical structures. As technology evolves, so do our building materials, and higher strength concrete can be produced at lower cost. As a result, the use of smaller cross-sections of columns can be advantageous.

As the columns become slenderer, stability issues and the calculation of second-order effects become more important. The ConSteel finite element program specializes in steel structures and therefore has fast and well automated solutions to stability problems.

Taking advantage of the existing features of the software, a new method for designing reinforced concrete columns, improved by ConSteel, has been made available in ConSteel version 16. It is based on the Nominal Curvature method described in Eurocode 5.8.8 [1].

To apply the Nominal Curvature Method, a lot of information is required, various material and geometric parameters. The purpose of this article is to show that the Nominal Curvature Method, as extended in ConSteel 16, answers all the questions that arise during design and is free of many of the shortcomings of the original method.

Overview of Eurocode 2 - desinging reinforced concrete columns

In this chapter, the design of reinforced concrete columns based on Eurocode 2, nominal curvature method, is presented in outline, focusing on the most important aspects. 

Material parameters

Partial safety factors:

  • Modulus of elasticity of concrete
    𝛾cE = 1.20
  • Concrete
    𝛾c = 1.50
  • Steel reinforcement
    𝛾s = 1.15

The material properties of concrete are dealt with in Eurocode 1992-1-1, Chapter 3.1.

Modulus of elasticity:

  • Design value
    • 𝐸cd = 𝐸cmcE
    • Reducing the mean value with γcE partial safety factor
    • Applicable in ULS
    • In the case where creep is not considered, or considered elsewhere

Creep

The calculation of the creep coefficient is discussed in EN 1992-1-1, chapter 3.1.4. Here, various factors are used to determine the final value of the creep coefficient as a function of concrete strength, using diagrams. The values can also be determined according to Annex B of EN 1992-1-1. The two calculations give almost identical results.

Imperfections

The imperfections of concrete buildings are discussed in Eurocode 1992-1-1, Chapter 5.2. It divides the imperfections into two parts. One is the global inclination, which is shown in Figure 1(b). The other part is when the network points are not displaced but the elements in between are curved. This is the initial curvature (also known as a shape error), illustrated in part c) of Figure 1.

calculation of an imperfect structure according to Eurocode
Figure 1: Calculation of an imperfect structure according to Eurocode: a) imperfect frame, b) global skewness with substitute horizontal loads, c) elements curved at their original grid point [5]

Inclination

The effect of imperfection due to inclination can be taken into account by calculating fictitious transverse forces (nominal loads). To do this, the value of the applied inclination is calculated as follows:

  • Base value of inclination
    θ0 = 1/200
  • Height-dependent reduction factor
    αh = 2/√𝐻

    where 𝐻 is the height
  • reduction factor depending on the number of structural elements
    αm = √0.5(1 + 1/𝑚)

    𝑚: number of vertical structural elements bearing the total load
  • applied inclination
    θi = θ0αhαm                   

Then, as shown in Figure 2, the 𝑁 the normal forces can be used to calculate the notional loads in the unbraced case: 𝐻i = θi𝑁.

In braced case, for example a hinged-hinged column, 𝐻i  force is not defined at the top of the column, but at the center, with the value: 𝐻i = 2θi𝑁.

Isolated member with eccentric axial force or lateral force. Unbraced (left) and braced (right) - EN 1992-1-1 Figure 5.1(a) [1]
Figure 2: Isolated member with eccentric axial force or lateral force. Unbraced (left) and braced (right) - EN 1992-1-1 Figure 5.1(a) [1]

Second order effects

The method described in EN 1992-1-1, chapter 5.8.8, is applicable by default to isolated columns with constant cross-section and normal forces.

The design method uses the maximum second-order moment (𝑀2). Its distribution along the length is not directly determined. For the sake of simplicity and to be conservative, it is usual to assume this second order bending moment to be uniform along the length, but the standard also permits a sinusoidal or parabolic distribution.

If we can realistically determine the distribution of curvature, the Eurocode allows the use of the method for global structures (EN 1992-1-1 5.8.5 (3)), but this is not usually possible for manual methods due to the interactions between the elements.

To use this method, it is essential to specify the buckling length, the value of the second order bending moment depends on it. For this purpose, the standard allows the use of the factors used in the elastic theory (for cantilever 𝑙0 = 2𝐻, fix bottom - top hinged case 𝑙0 = 0.7𝐻, etc.).

Calculation of design bending moment:

𝑀Ed = 𝑀0Ed + 𝑀2

where

𝑀0Ed is the 1st order moment, including the effect of imperfections

𝑀2 is the nominal 2nd order moment (including the effect of any curvature)

Calculation of second order bending moment from curvature

Determine the nominal curvature first:

1/𝑟 = 𝐾r𝐾φ1/𝑟0

where

  • 𝐾r is a correction factor depending on axial load
  • 𝐾φ is a factor for taking account of creep
  • 1/𝑟0 is the theoretical (physical) curvature associated with failure

1/𝑟0 = ε𝑦𝑑/0,45𝑑

The curvature belongs to the point where the concrete reaches its ultimate compressive strength ( ) and the tensioned reinforcement is starting to yield, i.e. the so-called “balanced” case.

The position on the design line is taken into account by the correction factor depending on axial load:

𝐾r = (𝑛u − 𝑛)/(𝑛u − 𝑛bal)

where

  • 𝑛 = 𝑁Ed / Ac𝑓cd
    relative axial force
    • 𝑁Ed
      design value of axial force
  • 𝑛u=1+ω
    • ω = As𝑓yd / Ac𝑓cd
      mechanical reinforcement ratio
    • As
      is the total area of reinforcement
    • Ac
      is the area of concrete cross-section
  • 𝑛bal =0.4
    value of n at maximum bending
  • (0.4 applicable in the absence of further information)

Factor for taking account of creep:

𝐾φ = 1 + βφef ≥ 1

where

  • φef = φ(∞,0) 𝑀0Eqp / 𝑀0Ed
    effective creep
    • 𝑀0Eqp first order quasi-permanent bending moment (SLS)
    • 𝑀0Ed first order bending moment (ULS) – design combination
  • β=0,35 + 𝑓ck/200−λ/150
    • λ = 𝑙0 / 𝑖
      slenderness
    • 𝑙0
      buckling length
    • i = √𝐼c/𝐴c
      inertia radius of uncracked concrete

Second order bending moment

𝑀2=𝑁Ed𝑒2

where

Second order eccentricity, where c is the factor depending on the curvature distribution. For constant cross-section 𝑐=𝜋2 applicable (sinusoidal distribution). In case of constant distribution 𝑐=8 is applicable.

Design

Column Interaction Curve

According to the Interaction Curve, the failure of the cross-section always occurs, when the concrete reaches its ultimate strain (usually 𝜀cd = 0,35%).

Depending on where we are on the interaction curve, the reinforcement on the other side:

  • Tensioned, and yielding,
  • Tensioned, and just started yielding,
  • Tensioned, but elastic,
  • Compressed and elastic.
Reinforced-concrete-column-interaction-curve
Figure 3. Reinforced-concrete-column-interaction-curve

Theoretical background of the development

The design procedure is an extension of the standard procedure described in Chapter 2. It automates the manual entry of the buckling lengths and defines the distribution of the second order bending moments.

The initial value of the curvature distribution on which the calculation is based is performed on the global structure and not on an isolated column. The curvature distribution is determined from the elastic buckling shapes calculated on the whole structure (Linear Buckling Analysis - LBA).

This can be considered a realistic curvature distribution for the concrete column because we calculate the buckling shape for the entire structure, taking into account the interaction of the structural elements.

This allows the method to be extended, so that the column can now be considered not only as an isolated element, but also as part of the whole structure, in accordance with the Eurocode (EN 1992-1-1 5.8.5 (3)).

The final step, the calculation of second order bending moments (𝑀2), is performed on an isolated model in the spirit of the standard, but for this curvature it uses the values of the corresponding buckling shape along the column calculated on the full model.

The maximum value of the buckling shape for the curvature prescribed by the standard (1/𝑟) and the other values are varied in proportion.

The appropriate eigenvalue assignment is done by a procedure called buckling sensitivity analysis. Magnification is performed at the point of maximum curvature found along the length of the column.

With this method, we could theoretically calculate second-order moments for any structural element and the entire structure. However, at this stage of development, it is only considered for straight-axis beam elements defined as reinforced concrete columns.

Later on, if the need arises, the procedure can be developed into a general procedure after proper testing and verification. This could be a very useful feature for example for reinforced concrete arches or reinforced concrete frame columns with moment restraints.

Buckling sensitivity analysis

The main difficulty of the method is to find the right buckling shapes for the corresponding RC columns ins both direction (x and y). The program calculates a number of buckling shapes defined by the user.

Assuming each shape as a displaced shape, the summed deformation energy per bar element is calculated along each bar element of the structure.

The element with the highest deformation energy value calculated on the basis of the buckling length just tested is assigned a value of 100%, the other elements a proportional value. The buckling shape currently under consideration is assigned to the corresponding bar element.

Since a column can generally bend in both perpendicular directions, the test is performed in both local directions and 2 eigenvalues are assigned to each column (1-1 per direction).

Calculation of second order bending moments

According to Eurocode:

𝑀2 = 𝑁Ed𝑒2

where 𝑐 = π2

ConSteel calculates in a similar manner. Second order moments are calculated for each finite element of the reinforced concrete column. Three values are used. The first is the normal load at the finite element point (𝑁Ed). The second is the second order eccentricity as defined in the Eurocode (𝑒2).

After that, the third value is the ordinate of the buckling shape at the given finite element point, with the maximum of the buckling shape normalized to the unit value. Simply put, multiplying the first two values by this third value gives the second order moment at the given finite element point of the reinforced concrete column. This results in an improved moment distribution.

Differences compared to the standard procedure

Simplification of the calculation of the effective creep:

φef = φ(∞,𝑡0)

conservatively, we equate the effective creep with the final value of the creep factor, without reduction. This avoids errors such as, for example, if there is no bending moment in a quasi-permanent load combination, then the value of the effective creep factor is by definition zero.

Creep factor value in ConSteel

The values given in ConSteel are taken from Table 1 of the Eurocode guide for Reinforced Concrete Structures [6].

This is based on EN 1992-1-1, chapter 3.1.4, where various factors can be used to determine the final value of the creep factor as a function of concrete strength, using diagrams. 

Calculation of slenderness based on buckling analysis

Critical strength of the Euler beam. The formula rearranged:

where

There is no need to manually enter the buckling length, the slenderness calculation is fully automated.

Second order bending moment distribution

The distribution of the second order bending moment is the same as the buckling shape, taking into account the interaction between columns.

Demonstration of the method using a console example

You can see how to make the example model in our Reinforced Concrete Column - overview article.

Download the starter model at the end of this article and open the "separate_circle_column_cantilever.csm" file.

First order analysis

first order analysis of a reinforced concrete column in Consteel
First order analysis of a reinforced concrete column in Consteel 16

Displacement shape: realistic values:

  • Slight vertical displacement
  • in the direction where a greater horizontal load is applied, greater displacement
  • slight displacement in the other direction due to the imperfection
  • the displacement shape is curved in the direction of the horizontal load as expected

Check the internal forces:

internal forces in first order analysis of a reinforced concrete column in Consteel
Internal forces - N in first order analysis of a reinforced concrete column in Consteel 16

N

  • same as the vertical load, with constant distribution (no self-weight applied in the model)

negative sign -> compression

Vy+Mz

  • we calculate the imperfection from the normal force
  • 675*0,005 = 3,375 kN
  • 3,38*3 = 10,14 kNm
  • Distributions and valuer are as expected
  • No Vy+Mz from applied loads, only from imperfection
internal-forces-Vy-in-first-order-analysis-of-a-reinforced-concrete-column-in-Consteel
Internal forces - Vy in first order analysis of a reinforced concrete column in Consteel
internal forces - Mz in first order analysis of a reinforced concrete column in Consteel
Internal forces - Mz in first order analysis of a reinforced concrete column in Consteel 16

Vz +My

  • Imperfection calculated form the normal force
  • 675*0,005 = 3,375 kN
  • 3,38*3 = 10,14 kNm
  • These internal forces are calculated from imperfection
  • Additional 20*1,5 = 30 kN load
  • 30+3,375 = 33,375 kNm
  • 33,375*3 = 100,125 kNm
  • Correct internal forces
  • first order internal loads from applied loads + inclination
internal forces - My in first order analysis of a reinforced concrete column in Consteel
Internal forces - My in first order analysis of a reinforced concrete column in Consteel 16
internal forces - Vz in first order analysis of a reinforced concrete column in Consteel
Internal forces - Vz in first order analysis of a reinforced concrete column in Consteel 16

Buckling analysis & buckling sensitivity analysis

buckling analysis of a reinforced concrete column in Consteel
Buckling analysis of a reinforced concrete column in Consteel 16 - buckling shape in x direction

We can see from the coordinates, that this is indeed a planar buckling shape.

For a single column, it is rather easy, to check whether we have buckling shape in both directions. Here we only found one, so we need to find the other one as well.

buckling sensitivity of a reinforced concrete column in Consteel
Buckling sensitivity of a reinforced concrete column in Consteel 16 - for first buckling shape: x direction

Parameters of the buckling analysis need to be adjusted. We should increase the upper limit of the calculated number of buckling shapes.

Download the adjusted model at the end of this article and open the "separate_circle_column_cantilever_MoreBucklingShape.csm" file.

Now we have buckling shape in both x and y directions.

buckling analysis of a reinforced concrete column in Consteel - y direction
Buckling analysis of a reinforced concrete column in Consteel - buckling shape in y direction
buckling sensitivity of a reinforced concrete column in Consteel - y direction
Buckling sensitivity of a reinforced concrete column in Consteel - second buckling shape: y direction

ULS design - EN 1992 condition

Everything is symmetrical.